SunGuard® Solar Neutral 67     

SunGuard® Solar Green 52

SunGuard® Solar Light Blue 52

SunGuard® Solar Green 32

SunGuard® Solar Silver Grey 32

SunGuard® Solar Green 30

SunGuard® Solar Pewter 30

SunGuard® Solar Aquamarine 20

SunGuard® Solar Royal Blue 20

SunGuard® Solar Green 20

SunGuard® Solar Silver 08

SunGuard® Solar Green 10

SunGuard® Solar Silver 20

SunGuard® Solar Grey 32

SunGuard® Solar Silver 10

SunGuard® Solar Grey 10

SunGuard® Solar Green 67 

SunGuard® Solar Silver Green 08

SunGuard® Solar Green 52 Radar

SunGuard® Solar Light Blue 52 Radar

On request, this type of data is available for any Guardian coating which is not listed below
 
 
SunGuard® Solar Neutral 67     

1

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Neutral 67

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,67

0,67

0,67

0,67

0,67

0,66

0,65

Light reflection (coated side / glass side) rV

0,15 / 0,17

0,15 / 0,17

0,15 / 0,17

0,15 / 0,17

0,15 / 0,16

0,15 / 0,16

0,15 / 0,16

Solar energy transmission tE 

0,64

0,63

0,62

0,62

0,60

0,58

0,57

Solar energy reflection (coated side / glass side)   rE 

0,13 / 0,13

0,13 / 0,13

0,13 / 0,13

0,13 / 0,12

0,13 / 0,12

0,13 / 0,12

0,13 / 0,12

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Light Blue 52

2

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Light Blue 52

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,52

0,52

0,52

0,52

0,51

0,51

0,51

Light reflection (coated side / glass side) rV

0,11 / 0,13

0,11 / 0,13

0,11 / 0,13

0,11 / 0,13

0,11 / 0,13

0,11 / 0,13

0,11 / 0,13

Solar energy transmission tE 

0,45

0,44

0,43

0,43

0,42

0,41

0,40

Solar energy reflection (coated side / glass side)   rE 

0,14 / 0,12

0,14 / 0,11

0,14 / 0,11

0,14 / 0,11

0,14 / 0,11

0,14 / 0,11

0,14 / 0,10

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Silver Grey 32     

3

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Silver Grey 32

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,32

0,32

0,32

0,32

0,32

0,32

0,31

Light reflection (coated side / glass side) rV

0,16 / 0,22

0,16 / 0,22

0,16 / 0,22

0,16 / 0,22

0,16 / 0,22

0,16 / 0,22

0,16 / 0,21

Solar energy transmission tE 

0,26

0,26

0,26

0,26

0,25

0,24

0,24

Solar energy reflection (coated side / glass side)   rE 

0,23 / 0,21

0,23 / 0,20

0,23 / 0,20

0,23 / 0,19

0,23 / 0,19

0,23 / 0,18

0,23 / 0,18

NPD = No Performance Determined

back to top  

 

SunGuard® Solar Pewter 30

4

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Pewter 30

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,29

0,29

0,29

0,29

0,29

0,29

0,29

Light reflection (coated side / glass side) rV

0,19 / 0,21

0,19 / 0,21

0,19 / 0,21

0,19 / 0,21

0,19 / 0,20

0,19 / 0,20

0,19 / 0,20

Solar energy transmission tE 

0,24

0,24

0,24

0,23

0,23

0,22

0,22

Solar energy reflection (coated side / glass side)   rE 

0,26 / 0,20

0,26 / 0,20

0,26 / 0,19

0,26 / 0,19

0,26 / 0,18

0,26 / 0,17

0,26 / 0,17

NPD = No Performance Determined

back to top  

 

SunGuard® Solar Royal Blue 20     

5

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Royal Blue 20

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,22

0,22

0,22

0,22

0,22

0,22

0,21

Light reflection (coated side / glass side) rV

0,33 / 0,18

0,33 / 0,18

0,33 / 0,18

0,33 / 0,18

0,33 / 0,18

0,33 / 0,18

0,33 / 0,17

Solar energy transmission tE 

0,19

0,19

0,19

0,19

0,18

0,18

0,17

Solar energy reflection (coated side / glass side)   rE 

0,36/ 0,19

0,36/ 0,19

0,36/ 0,18

0,36/ 0,18

0,36/ 0,18

0,36/ 0,17

0,36/ 0,16

NPD = No Performance Determined

back to top  

 

SunGuard® Solar Silver 20     

6

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Silver 20

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,21

0,21

0,21

0,21

0,21

0,21

0,21

Light reflection (coated side / glass side) rV

0,20 / 0,35

0,20 / 0,34

0,20 / 0,34

0,20 / 0,34

0,20 / 0,34

0,20 / 0,33

0,20 / 0,33

Solar energy transmission tE 

0,18

0,17

0,17

0,17

0,17

0,16

0,16

Solar energy reflection (coated side / glass side)   rE 

0,30 / 0,35

0,30 / 0,34

0,30 / 0,33

0,30 / 0,32

0,30 / 0,31

0,30 / 0,30

0,30 / 0,29

NPD = No Performance Determine

back to top  

 

SunGuard® Solar Silver 10     

7

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Silver 10

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,11

0,11

0,11

0,10

0,10

0,10

0,10

Light reflection (coated side / glass side) rV

0,34 / 0,45

0,34 / 0,45

0,34 / 0,45

0,34 / 0,45

0,34 / 0,44

0,34 / 0,43

0,34 / 0,43

Solar energy transmission tE 

0,09

0,08

0,08

0,08

0,08

0,08

0,08

Solar energy reflection (coated side / glass side)   rE 

0,42 / 0,43

0,42 / 0,42

0,42 / 0,41

0,42 / 0,40

0,42 / 0,39

0,42 / 0,37

0,42 / 0,35

NPD = No Performance Determined

back to top  

 

SunGuard® Solar Green 67     

8

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 67 

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,60

0,58

0,56

0,54

0,50

0,46

0,43

Light reflection (coated side / glass side) rV

0,14 / 0,14

0,14 / 0,14

0,14 / 0,13

0,14 / 0,12

0,14 / 0,11

0,14 / 0,10

0,14 / 0,10

Solar energy transmission tE 

0,44

0,39

0,35

0,32

0,26

0,23

0,20

Solar energy reflection (coated side / glass side)   rE 

0,13 / 0,10

0,12 / 0,09

0,12 / 0,08

0,12 / 0,08

0,12 / 0,07

0,12 / 0,07

0,12 / 0,06

NPD = No Performance Determined

back to top  

 

SunGuard® Solar Green 52     

9

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 52

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,47

0,45

0,43

0,42

0,39

0,36

0,33

Light reflection (coated side / glass side) rV

0,11 / 0,11

0,10 / 0,11

0,10 / 0,10

0,10 / 0,09

0,10 / 0,09

0,10 / 0,09

0,10 / 0,08

Solar energy transmission tE 

0,31

0,28

0,26

0,23

0,20

0,17

0,15

Solar energy reflection (coated side / glass side)   rE 

0,14 / 0,08

0,14 / 0,08

0,14 / 0,07

0,14 / 0,07

0,14 / 0,07

0,14 / 0,06

0,14 / 0,06

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Green 32     

10

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 32

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,29

0,28

0,27

0,26

0,24

0,22

0,21

Light reflection (coated side / glass side) rV

0,16 / 0,19

0,16 / 0,18

0,16 / 0,17

0,16 / 0,16

0,16 / 0,14

0,16 / 0,13

0,16 / 0,12

Solar energy transmission tE 

0,19

0,17

0,16

0,14

0,12

0,11

0,10

Solar energy reflection (coated side / glass side)   rE 

0,23 / 0,13

0,23 / 0,12

0,23 / 0,11

0,23 / 0,10

0,23 / 0,09

0,23 / 0,08

0,23 / 0,07

NPD = No Performance Determined


back to top 

 

SunGuard® Solar Green 30

11

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 30

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,26

0,25

0,24

0,24

0,22

0,20

0,19

Light reflection (coated side / glass side) rV

0,19 / 0,18

0,19 / 0,17

0,19 / 0,16

0,19 / 0,15

0,19 / 0,13

0,19 / 0,12

0,19 / 0,11

Solar energy transmission tE 

0,17

0,16

0,14

0,13

0,11

0,10

0,09

Solar energy reflection (coated side / glass side)   rE 

0,26 / 0,12

0,26 / 0,11

0,26 / 0,10

0,26 / 0,09

0,26 / 0,08

0,26 / 0,07

0,26 / 0,07

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Aquamarine 20     

12

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Aquamarine 20

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,20

0,19

0,18

0,18

0,16

0,15

0,14

Light reflection (coated side / glass side) rV

0,33 / 0,16

0,33 / 0,15

0,33 / 0,14

0,33 / 0,13

0,33 / 0,12

0,33 / 0,11

0,33 / 0,10

Solar energy transmission tE 

0,13

0,12

0,11

0,10

0,08

0,07

0,06

Solar energy reflection (coated side / glass side)   rE 

0,36 / 0,12

0,36 / 0,11

0,36 / 0,10

0,36 / 0,09

0,36 / 0,08

0,36 / 0,08

0,36 / 0,07

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Green 20

13

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 20

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,19

0,19

0,18

0,17

0,16

0,15

0,14

Light reflection (coated side / glass side) rV

0,20 / 0,29

0,20 / 0,27

0,20 / 0,25

0,20 / 0,24

0,20 / 0,21

0,20 / 0,19

0,20 / 0,17

Solar energy transmission tE 

0,13

0,11

0,10

0,20

0,08

0,07

0,06

Solar energy reflection (coated side / glass side)   rE 

0,29 / 0,19

0,29 / 0,17

0,29 / 0,15

0,29 / 0,14

0,29 / 0,12

0,29 / 0,10

0,29 / 0,09

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Green 10     

14

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 10

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,09

0,09

0,09

0,08

0,08

0,07

0,07

Light reflection (coated side / glass side) rV

0,34 / 0,37

0,34 / 0,34

0,34 / 0,32

0,34 / 0,30

0,34 / 0,27

0,34 / 0,23

0,34 / 0,21

Solar energy transmission tE 

0,06

0,06

0,05

0,05

0,04

0,04

0,03

Solar energy reflection (coated side / glass side)   rE 

0,42 / 0,24

0,42 / 0,20

0,42 / 0,18

0,42 / 0,16

0,42 / 0,14

0,42 / 0,12

0,42 / 0,11

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Grey 32     

15

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Grey 32

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,23

0,20

0,18

0,16

0,12

0,10

0,08

Light reflection (coated side / glass side) rV

0,15 / 0,13

0,15 / 0,11

0,15 / 0,10

0,15 / 0,09

0,15 / 0,07

0,15 / 0,06

0,15 / 0,05

Solar energy transmission tE 

0,19

0,17

0,15

0,13

0,11

0,09

0,07

Solar energy reflection (coated side / glass side)   rE 

0,23 / 0,13

0,23 / 0,11

0,23 / 0,10

0,23 / 0,09

0,23 / 0,07

0,23 / 0,06

0,23 / 0,06

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Grey 10     

16

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Grey 10

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,07

0,07

0,06

0,05

0,04

0,03

0,02

Light reflection (coated side / glass side) rV

0,34 / 0,24

0,34 / 0,20

0,34 / 0,17

0,34 / 0,14

0,34 / 0,10

0,34 / 0,08

0,34 / 0,07

Solar energy transmission tE 

0,06

0,05

0,05

0,04

0,03

0,03

0,02

Solar energy reflection (coated side / glass side)   rE 

0,42 / 0,25

0,42 / 0,21

0,42 / 0,17

0,42 / 0,15

0,42 / 0,11

0,42 / 0,09

0,42 / 0,07

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Silver 08

17

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Silver 08

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,09

0,09

0,09

0,09

0,09

0,09

0,09

Light reflection (coated side / glass side) rV

0,30 / 0,44

0,30 / 0,44

0,30 / 0,43

0,30 / 0,43

0,30 / 0,43

0,30 / 0,42

0,30 / 0,41

Solar energy transmission tE 

0,08

0,08

0,08

0,08

0,08

0,08

0,08

Solar energy reflection (coated side / glass side)   rE 

0,41 / 0,37

0,41 / 0,36

0,41 / 0,35

0,41 / 0,35

0,41 / 0,34

0,41 / 0,32

0,41 / 0,31

NPD = No Performance Determined

back to top 

 

SunGuard® Solar Silver Green 08     

18

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Silver Green 08

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,08

0,08

0,07

0,07

0,07

0,06

0,06

Light reflection (coated side / glass side) rV

0,30 / 0,36

0,30 / 0,34

0,30 / 0,32

0,30 / 0,30

0,30 / 0,26

0,30 / 0,23

0,30 / 0,21

Solar energy transmission tE 

0,06

0,05

0,05

0,04

0,04

0,03

0,03

Solar energy reflection (coated side / glass side)   rE 

0,41 / 0,22

0,41 / 0,19

0,41 / 0,17

0,41 / 0,16

0,41 / 0,13

0,41 / 0,12

0,41 / 0,10

NPD = No Performance Determined

back to top 


 

SunGuard® Solar Green 52 Radar     

19

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Green 52 Radar

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,54

0,52

0,50

0,48

0,44

0,41

0,38

Light reflection (coated side / glass side) rV

0,12 / 0,12

0,12 / 0,12

0,12 / 0,12

0,12 / 0,11

0,12 / 0,10

0,12 / 0,09

0,12 / 0,09

Solar energy transmission tE 

0,39

0,34

0,31

0,28

0,23

0,20

0,18

Solar energy reflection (coated side / glass side)   rE 

0,13 / 0,09

0,13 / 0,08

0,13 / 0,08

0,13 / 0,07

0,12 / 0,07

0,12 / 0,06

0,12 / 0,06



NPD = No Performance Determined

back to top 

SunGuard® Solar Light Blue 52 Radar     

20

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® Solar Light Blue 52 Radar

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated surface en

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,60

0,60

0,60

0,59

0,59

0,59

0,58

Light reflection (coated side / glass side) rV

0,13 / 0,14

0,13 / 0,14

0,13 / 0,14

0,13 / 0,14

0,13 / 0,14

0,13 / 0,14

0,13 / 0,14

Solar energy transmission tE 

0,56

0,56

0,55

0,54

0,53

0,51

0,50

Solar energy reflection (coated side / glass side)   rE 

0,14 / 0,12

0,14 / 0,12

0,13 / 0,11

0,13 / 0,11

0,13 / 0,11

0,13 / 0,11

0,13 / 0,11

NPD = No Performance Determined

back to top