GUARDIAN CE-MARKING

   
Coated Glass
   Low Emissivity Glass
     ClimaGuard® A
     ClimaGuard® 1.0
     ClimaGuard® N
     ClimaGuard® NL
     ClimaGuar® N3
     ClimaGuard® D
     ClimaGuard® Premium
     ClimaGuard® Solar
   Solar Control Glass
     SunGuard E-Performance
     SunGuard Solar
     SunGuard High Performance
     SunGuard High Selective
Acid Etched Glass
     SATINDECO
Float Glass
     Clear Float
     ExtraClear™
     ExtraClear™ Plus
Colored Float Glass
     Float Green
     Float Grey
     Float Bronze
Heat Treated Glass
Laminated Safety Glass
     L. S. Glass
     L. S. Soundcontrol Glass
     L. S. Glass - ExtraClear
Patterned Glass
Low Iron Patterned Glass
FAQ's
Useful Weblinks
Additional Translations
Site Map
Import Html
Terms of use
Privacy Statement

SunGuard® HP Light Blue 63      

1

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Light Blue 63

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,14

0,14

0,14

0,14

0,14

0,14

0,14

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,68

0,68

0,68

0,68

0,67

0,67

0,66

Light reflection (coated side / glass side) rV

0,04 / 0,12

0,04 / 0,12

0,04 / 0,12

0,04 / 0,12

0,04 / 0,12

0,04 / 0,12

0,04 / 0,12

Solar energy transmission tE 

0,56

0,55

0,55

0,54

0,53

0,51

0,51

Solar energy reflection (coated side / glass side) rE 

0,15 / 0,15

0,15 / 0,15

0,15 / 0,15

0,15 / 0,14

0,15 / 0,14

0,15 / 0,13

0,15 / 0,13

NPD = No Performance Determined

back to top

SunGuard® HP Neutral 61   

2

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Neutral 61

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,05

0,05

0,05

0,05

0,05

0,05

0,05

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,63

0,63

0,62

0,62

0,62

0,62

0,61

Light reflection (coated side / glass side) rV

0,08 / 0,19

0,08 / 0,19

0,08 / 0,19

0,08 / 0,19

0,08 / 0,19

0,08 / 0,19

0,08 / 0,19

Solar energy transmission tE 

0,45

0,44

0,44

0,44

0,43

0,42

0,41

Solar energy reflection (coated side / glass side) rE 

0,28 / 0,30

0,29 / 0,29

0,29 / 0,28

0,29 / 0,27

0,29 / 0,26

0,29 / 0,24

0,29 / 0,24

NPD = No Performance Determined

back to top

SunGuard® HP Neutral 50   

3

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Neutral 50

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,11

0,11

0,11

0,11

0,11

0,11

0,11

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,57

0,57

0,57

0,57

0,57

0,56

0,56

Light reflection (coated side / glass side) rV

0,03 / 0,15

0,03 / 0,15

0,03 / 0,15

0,03 / 0,15

0,03 / 0,15

0,03 / 0,15

0,03 / 0,15

Solar energy transmission tE 

0,44

0,44

0,43

0,43

0,42

0,41

0,40

Solar energy reflection (coated side / glass side) rE 

0,19/ 0,21

0,19/ 0,20

0,19/ 0,20

0,19/ 0,19

0,19/ 0,19

0,19/ 0,18

0,19/ 0,17

NPD = No Performance Determined

back to top

Sunguard® HP Silver 43

4

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Silver 43

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,05

0,05

0,05

0,05

0,05

0,05

0,05

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,47

0,47

0,47

0,47

0,47

0,47

0,46

Light reflection (coated side / glass side) rV

0,09 / 0,30

0,09 / 0,30

0,09 / 0,30

0,09 / 0,30

0,09 / 0,30

0,09 / 0,29

0,09 / 0,29

Solar energy transmission tE 

0,33

0,33

0,32

0,32

0,32

0,31

0,30

Solar energy reflection (coated side / glass side) rE 

0,32/ 0,38

0,32/ 0,37

0,32/ 0,36

0,32/ 0,35

0,32/ 0,34

0,32/ 0,32

0,32/ 0,31

NPD = No Performance Determined

back to top

 

SunGuard® HP Neutral 40   

5

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Neutral 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,11

0,11

0,11

0,11

0,11

0,11

0,11

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,45

0,45

0,45

0,45

0,45

0,44

0,44

Light reflection (coated side / glass side) rV

0,04 / 0,21

0,04 / 0,20

0,04 / 0,20

0,04 / 0,20

0,04 / 0,20

0,04 / 0,20

0,04 / 0,20

Solar energy transmission tE 

0,34

0,34

0,33

0,33

0,32

0,31

0,31

Solar energy reflection (coated side / glass side) rE 

0,23 / 0,25

0,23 / 0,25

0,23 / 0,24

0,23 / 0,24

0,23 / 0,23

0,23 / 0,21

0,23 / 0,21

NPD = No Performance Determined

back to top

 

SunGuard® HP Royal Blue 40

6

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Royal Blue 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,09

0,09

0,09

0,09

0,09

0,09

0,09

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,42

0,42

0,42

0,42

0,42

0,42

0,41

Light reflection (coated side / glass side) rV

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,23

Solar energy transmission tE 

0,32

0,32

0,31

0,31

0,30

0,29

0,29

Solar energy reflection (coated side / glass side) rE 

0,28 / 0,27

0,28/ 0,26

0,28 / 0,25

0,28 / 0,25

0,28 / 0,24

0,28 / 0,23

0,28 / 0,22

NPD = No Performance Determined

back to top

 

SunGuard® HP Green 63

7

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 63

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,14

0,14

0,14

0,14

0,14

0,14

0,14

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,61

0,59

0,57

0,55

0,51

0,47

0,43

Light reflection (coated side / glass side) rV

0,04 / 0,11

0,03 / 0,10

0,03 / 0,10

0,03 / 0,09

0,03 / 0,09

0,03 / 0,08

0,03 / 0,08

Solar energy transmission tE 

0,40

0,36

0,32

0,30

0,25

0,22

0,19

Solar energy reflection (coated side / glass side) rE 

0,14 / 0,10

0,14 / 0,09

0,14 / 0,08

0,14 / 0,07

0,14 / 0,07

0,14 / 0,06

0,14 / 0,06

back to top

 

SunGuard® HP Green 61

8

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 61

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,05

0,05

0,05

0,05

0,05

0,05

0,05

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,56

0,54

0,52

0,50

0,46

0,43

0,40

Light reflection (coated side / glass side) rV

0,08/ 0,16

0,08 / 0,16

0,08 / 0,15

0,08 / 0,14

0,08 / 0,13

0,08 / 0,12

0,08 / 0,11

Solar energy transmission tE 

0,33

0,30

0,27

0,25

0,22

0,19

0,17

Solar energy reflection (coated side / glass side) rE 

0,28 / 0,15

0,28/ 0,13

0,28 / 0,11

0,28 / 0,10

0,28 / 0,08

0,28 / 0,08

0,28 / 0,07

NPD = No Performance Determined

back to top

 

SunGuard® HP Green 64

9

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 64

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,04

0,04

0,04

0,04

0,04

0,04

0,04

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,79

0,76

0,73

0,70

0,65

0,60

0,56

Light reflection (coated side / glass side) rV

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,24

0,10 / 0,23

Solar energy transmission tE 

0,46

0,42

0,39

0,36

0,31

0,27

0,24

Solar energy reflection (coated side / glass side) rE 

0,26 / 0,12

0,26 / 0,09

0,26 / 0,08

0,26 / 0,07

0,26 / 0,06

0,26 / 0,05

0,26 / 0,05

NPD = No Performance Determined

back to top

 

SunGuard® HP Green 43

10

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 43

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,05

0,05

0,05

0,05

0,05

0,05

0,05

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,42

0,41

0,39

0,38

0,35

0,32

0,30

Light reflection (coated side / glass side) rV

0,09 / 0,25

0,09 / 0,24

0,09 / 0,22

0,09 / 0,21

0,09 / 0,19

0,09 / 0,17

0,09 / 0,15

Solar energy transmission tE 

0,24

0,22

0,20

0,19

0,16

0,14

0,13

Solar energy reflection (coated side / glass side) rE 

0,32 / 0,20

0,32 / 0,17

0,32 / 0,15

0,31 / 0,13

0,31 / 0,11

0,31 / 0,10

0,31 / 0,09

NPD = No Performance Determined

back to top

 

SunGuard® HP Green 40

11

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,11

0,11

0,11

0,11

0,11

0,11

0,11

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,41

0,39

0,38

0,36

0,34

0,31

0,29

Light reflection (coated side / glass side) rV

0,04 / 0,17

0,04 / 0,16

0,04 / 0,16

0,04 / 0,15

0,04 / 0,13

0,04 / 0,12

0,04 / 0,11

Solar energy transmission tE 

0,25

0,22

0,21

0,19

0,16

0,14

0,13

Solar energy reflection (coated side / glass side) rE 

0,22 / 0,14

0,22 / 0,12

0,22 / 0,11

0,22 / 0,10

0,22 / 0,08

0,22 / 0,08

0,22 / 0,07

NPD = No Performance Determined

back to top

 

SunGuard® HP Aquamarine 40

12

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Aquamarine 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,09

0,09

0,09

0,09

0,09

0,09

0,09

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,38

0,36

0,35

0,34

0,31

0,29

0,27

Light reflection (coated side / glass side) rV

0,10 / 0,21

0,10 / 0,20

0,10 / 0,18

0,10 / 0,17

0,10 / 0,16

0,10 / 0,14

0,10 / 0,13

Solar energy transmission tE 

0,23

0,21

0,19

0,17

0,15

0,13

0,11

Solar energy reflection (coated side / glass side) rE 

0,28 / 0,16

0,28/ 0,14

0,28 / 0,13

0,28 / 0,12

0,28 / 0,10

0,28 / 0,09

0,28 / 0,08

NPD = No Performance Determined

back to top

 

SunGuard® HP Grey 61

13

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Royal Blue 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,09

0,09

0,09

0,09

0,09

0,09

0,09

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,44

0,39

0,34

0,30

0,24

0,19

0,15

Light reflection (coated side / glass side) rV

0,08 / 0,12

0,07 / 0,10

0,07 / 0,09

0,07 / 0,08

0,07 / 0,07

0,07 / 0,06

0,07 / 0,05

Solar energy transmission tE 

0,32

0,29

0,26

0,23

0,18

0,14

0,12

Solar energy reflection (coated side / glass side) rE 

0,28 / 0,18

0,28/ 0,16

0,28 / 0,14

0,28 / 0,12

0,28 / 0,09

0,28 / 0,07

0,28 / 0,06

NPD = No Performance Determined

back to top

 

SunGuard® HP Grey 43

14

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Grey 43

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,05

0,05

0,05

0,05

0,05

0,05

0,05

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,33

0,29

0,26

0,23

0,18

0,14

0,11

Light reflection (coated side / glass side) rV

0,08 / 0,17

0,08 / 0,14

0,08 / 0,12

0,08 / 0,11

0,08 / 0,08

0,08 / 0,07

0,08 / 0,06

Solar energy transmission tE 

0,24

0,21

0,19

0,17

0,13

0,11

0,08

Solar energy reflection (coated side / glass side) rE 

0,31 / 0,23

0,31 / 0,19

0,31 / 0,16

0,31 / 0,14

0,31 / 0,11

0,31 / 0,08

0,31 / 0,07

NPD = No Performance Determined

back to top

 

SunGuard® HP Silver 35

15

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Silver 35

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,04

0,04

0,04

0,04

0,04

0,04

0,04

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,38

0,38

0,38

0,38

0,38

0,37

0,37

Light reflection (coated side / glass side) rV

0,18 / 0,43

0,18 / 0,43

0,18 / 0,43

0,18 / 0,42

0,18 / 0,42

0,18 / 0,42

0,18 / 0,41

Solar energy transmission tE 

0,28

0,27

0,27

0,27

0,26

0,26

0,25

Solar energy reflection (coated side / glass side) rE 

0,35/ 0,46

0,35/ 0,45

0,35/ 0,44

0,35/ 0,43

0,35/ 0,41

0,35/ 0,38

0,35/ 0,37

NPD = No Performance Determined

back to top

 

SunGuard® HP Silver Green 35

16

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,04

0,04

0,04

0,04

0,04

0,04

0,04

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,34

0,33

0,31

0,30

0,28

0,26

0,24

Light reflection (coated side / glass side) rV

0,18 / 0,35

0,18 / 0,33

0,18 / 0,31

0,18 / 0,29

0,18 / 0,26

0,18 / 0,23

0,18 / 0,20

Solar energy transmission tE 

0,20

0,18

0,17

0,15

0,13

0,11

0,10

Solar energy reflection (coated side / glass side) rE 

0,35 / 0,24

0,35 / 0,20

0,35 / 0,18

0,35 / 0,16

0,35 / 0,14

0,35 / 0,12

0,35 / 0,10

NPD = No Performance Determined

back to top

 

SunGuard® HP Neutral Plus 50

17

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Neutral Plus 50

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,03

0,03

0,03

0,03

0,03

0,03

0,03

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,55

0,55

0,54

0,54

0,54

0,54

0,53

Light reflection (coated side / glass side) rV

0,16 / 0,21

0,16 / 0,21

0,16 / 0,21

0,16 / 0,21

0,16 / 0,21

0,16 / 0,20

0,16 / 0,20

Solar energy transmission tE 

0,33

0,33

0,33

0,32

0,32

0,31

0,31

Solar energy reflection (coated side / glass side) rE 

0,45 / 0,40

0,45 / 0,38

0,45 / 0,37

0,45 / 0,36

0,45 / 0,34

0,45 / 0,31

0,45 / 0,30

NPD = No Performance Determined

back to top

 

SunGuard® HP Green Plus 50

18

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of September 2006

SunGuard® HP Green Plus 50

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,03

0,03

0,03

0,03

0,03

0,03

0,03

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,49

0,47

0,45

0,44

0,40

0,37

0,35

Light reflection (coated side / glass side) rV

0,16 / 0,18

0,16 / 0,17

0,16 / 0,16

0,16 / 0,15

0,16 / 0,13

0,16 / 0,12

0,16 / 0,11

Solar energy transmission tE 

0,25

0,23

0,21

0,20

0,17

0,15

0,14

Solar energy reflection (coated side / glass side) rE 

0,45 / 0,18

0,45 / 0,15

0,45 / 0,13

0,45 / 0,11

0,45 / 0,09

0,45 / 0,08

0,45 / 0,07

NPD = No Performance Determined

back to top

SunGuard® HP Neutral Plus 60

19

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of December 2009

SunGuard® HP Neutral Plus 60

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,04

0,04

0,04

0,04

0,04

0,04

0,04

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,62

0,62

0,62

0,61

0,61

0,61

0,60

Light reflection (coated side / glass side) rV

0,11 / 0,21

0,11 / 0,21

0,11 / 0,21

0,11 / 0,21

0,11 / 0,20

0,11 / 0,20

0,11 / 0,20

Solar energy transmission tE 

0,42

0,42

0,41

0,41

0,40

0,39

0,38

Solar energy reflection (coated side / glass side) rE 

0,35 / 0,36

0,35 / 0,35

0,35 / 0,34

0,35 / 0,33

0,35 / 0,31

0,35 / 0,29

0,35 / 0,28

NPD = No Performance Determined

back to top

 

SunGuard® HP Green Plus 60

20

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of December 2009

SunGuard® HP Green Plus 60

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,04

0,04

0,04

0,04

0,04

0,04

0,04

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,55

0,53

0,51

0,49

0,46

0,42

0,39

Light reflection (coated side / glass side) rV

0,10 / 0,18

0,10 / 0,17

0,10 / 0,16

0,10 / 0,15

0,10 / 0,14

0,10 / 0,12

0,10 / 0,11

Solar energy transmission tE 

0,31

0,28

0,26

0,24

0,21

0,19

0,17

Solar energy reflection (coated side / glass side) rE 

0,35 / 0,17

0,35 / 0,14

0,35 / 0,12

0,35 / 0,11

0,35 / 0,09

0,35 / 0,08

0,35 / 0,07

NPD = No Performance Determined

back to top

SunGuard® HP Amber 40

21

Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg

EN 1096-4

Coated soda lime silicate glass
intended to be used in buildings and construction works
Values as of December 2009

SunGuard® HP Amber 40

3 mm

4 mm

5 mm

6 mm

8 mm

10 mm

12 mm

Resistance to fire 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Reaction to fire 

A1

A1

A1

A1

A1

A1

A1

External fire performance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Bullet resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Explosion resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Burglar resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Pendulum body impact resistance 

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Resistance against sudden temperature changes and temperature differentials

K

40

40

40

40

40

40

40

Wind, snow, permanent and imposed load resistance

mm

3

4

5

6

8

10

12

Direct airborne sound insulation

dB

28 (-1;-4)

29 (-2;-3)

30 (-1;-2)

31 (-2;-3)

32 (-2;-3)

33 (-2;-3)

34 (0;-2)

Thermal properties

Normal emissivity of coated glass surface  en

0,03

0,03

0,03

0,03

0,03

0,03

0,03

Thermal transmittance (U-value)

W/(m².K)

NPD

NPD

NPD

NPD

NPD

NPD

NPD

Radiation properties

Light transmission tV

0,45

0,45

0,44

0,44

0,44

0,44

0,43

Light reflection (coated side / glass side) rV

0,11 / 0,24

0,11 / 0,24

0,11 / 0,24

0,11 / 0,24

0,11 / 0,23

0,11 / 0,23

0,11 / 0,23

Solar energy transmission tE 

0,31

0,30

0,30

0,30

0,29

0,29

0,28

Solar energy reflection (coated side / glass side) rE 

0,35 / 0,39

0,35 / 0,38

0,35 / 0,37

0,35 / 0,36

0,35 / 0,34

0,35 / 0,31

0,35 / 0,30

NPD = No Performance Determined

back to top