ClimaGuard® NL ClimaGuard® NLT On request, this type of data is available for any Guardian coating which is not listed below. ClimaGuard®
NL
|

|
1
|
|
Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg
|
|
EN 1096-4
|
|
Coated soda lime silicate glass intended to be used in buildings and construction works
Values as of September 2006
|
|
ClimaGuard® N
|
4 mm
|
5 mm
|
6 mm
|
8 mm
|
10 mm
|
12 mm
|
|
Resistance to fire
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Reaction to fire
|
A1
|
A1
|
A1
|
A1
|
A1
|
A1
|
|
External fire performance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Bullet resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Explosion resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Burglar resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Pendulum body impact resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Resistance against sudden temperature changes and temperature differentials
|
K
|
40
|
40
|
40
|
40
|
40
|
40
|
|
Wind, snow, permanent and imposed load resistance
|
mm
|
4
|
5
|
6
|
8
|
10
|
12
|
|
Direct airborne sound insulation
|
dB
|
29 (-2;-3)
|
30 (-1;-2)
|
31 (-2;-3)
|
32 (-2;-3)
|
33 (-2;-3)
|
34 (0;-2)
|
|
Thermal properties
|
|
Normal emissivity of coated glass surface en
|
0,04
|
0,04
|
0,04
|
0,04
|
0,04
|
0,04
|
|
Thermal transmittance (U-value)
|
W/(m².K)
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Radiation properties
|
|
Light transmission tV
|
0,86
|
0,86
|
0,85
|
0,85
|
0,84
|
0,84
|
|
Light reflection (coated side / glass side) rV
|
0,05 / 0,06
|
0,05 / 0,06
|
0,05 / 0,06
|
0,05 / 0,06
|
0,05 / 0,06
|
0,05 / 0,06
|
|
Solar energy transmission
tE
|
0,63
|
0,63
|
0,62
|
0,62
|
0,59
|
0,58
|
|
Solar energy reflection (coated side / glass side) rE
|
0,25 / 0,21
|
0,25 / 0,20
|
0,25 / 0,20
|
0,25 / 0,19
|
0,25 / 0,17
|
0,25 / 0,17
|
NPD = No Performance Determined
back to top
ClimaGuard®
NLT
|

|
2
|
|
Guardian Europe S.à.r.l
Z.I. Wolser L-3452 Dudelange G.D. of Luxembourg
|
|
EN 1096-4
|
|
Temperable coated soda lime silicate glass intended to be used in buildings and construction works
Values as of September 2006
|
|
ClimaGuard® NLT
|
4 mm
|
5 mm
|
6 mm
|
8 mm
|
10 mm
|
12 mm
|
|
Resistance to fire
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Reaction to fire
|
A1
|
A1
|
A1
|
A1
|
A1
|
A1
|
|
External fire performance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Bullet resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Explosion resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Burglar resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Pendulum body impact resistance
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Resistance against sudden temperature changes and temperature differentials
|
K
|
40
|
40
|
40
|
40
|
40
|
40
|
|
Wind, snow, permanent and imposed load resistance
|
mm
|
4
|
5
|
6
|
8
|
10
|
12
|
|
Direct airborne sound insulation
|
dB
|
29 (-2;-3)
|
30 (-1;-2)
|
31 (-2;-3)
|
32 (-2;-3)
|
33 (-2;-3)
|
34 (0;-2)
|
|
Thermal properties
|
|
Normal emissivity of coated glass surface en
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Thermal transmittance (U-value)
|
W/(m².K)
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Radiation properties
|
|
Light transmission
tV
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Light reflection (coated side / glass side) rV
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
|
Solar energy transmission tE
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
NPD
|
|
Solar energy reflection (coated side / glass side) rE
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD/NPD
|
NPD = No Performance Determined
back to top
|